About 439,000 results
Open links in new tab
  1. THHN inside conduit - what to use inside wall cavity

    Aug 2, 2024 · The plain THHN had a higher temperature rating, significant when the conductors carry close to their rated amperage or the conduit or a drilled hole is stuffed with wires close to …

  2. THHN for underground installation? | Information by Electrical ...

    Apr 22, 2007 · Quick question, Is it permissible to pull THHN for an underground feed (the wires will be installed in pvc in the ground)? In a related question, when using expansion joints for …

  3. Does THHN/ Single Conductors have to be in conduit?

    Apr 5, 2019 · Such as THHN feeder wires for a sub-panel or some such. However, after looking in the code book, article 300.3 (A), states: single conductors specified in table 310.104 (A) shall …

  4. THHN vs. THWN-2 | Information by Electrical Professionals for ...

    Aug 14, 2024 · SIMpull THHN® Copper Wire 600 Volts. Copper Conductor. Thermoplastic Insulation/Nylon Sheath, Heat, Moisture, Gasoline and Oil Resistant II. All sizes rated both …

  5. THHN / THWN wire temperature rating | Information by Electrical ...

    Nov 15, 2018 · THHN is rated for 90 degree C and THWN is rated for 75 degree C but both of these ratings can be listed on the same wire. Just want to make sure I have this right, if …

  6. actual numbers of current carrying conductors in conduit

    Aug 10, 2009 · in the code book under emt conduit fill for #12 thhn,thwn it is allowed 16 number 12,but it also says that more than three current carrying conductors in raceway or cable,you …

  7. #8 on 50 amp breaker | Information by Electrical Professionals for ...

    Apr 22, 2024 · Hey all, I was recently called upon to inspect some EV charger circuits at a car dealership installed by another contractor. They used #8 THHN on 50 amp breakers for some …

  8. Best wire to sit in water "forever" | Information by Electrical ...

    Mar 13, 2010 · Most every conduit around here fills with water. We have always pulled in THHN/THWN wire, is that the best for longevity / safety?

  9. THHN Wire Without Conduit as Ground between Main and Subpanel

    Jan 14, 2025 · It would be easy to run a 10-AWG THHN wire along and through the overhead floor joists, but much more difficult to run conduit. Does NEC allow the use of a 10-AWG …

  10. THHN #6 stranded for GEC to ground rods... | Information by …

    Jun 27, 2021 · Given the price of copper, what are thoughts about using THHN (in the appropriate size) for the GEC? I need to update a 100-amp service in a small building. I have various …